Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 17 de 17
1.
J Am Coll Cardiol ; 83(13): 1225-1239, 2024 Apr 02.
Article En | MEDLINE | ID: mdl-38538202

BACKGROUND: Fetuses with cyanotic congenital heart disease (CHD) exhibit profound fetal circulatory disturbances that may affect early outcomes. OBJECTIVES: This study sought to investigate the relationship between fetal hemodynamics and early survival and neurodevelopmental (ND) outcomes in patients with cyanotic CHD. METHODS: In this longitudinal observational study, fetuses with cyanotic CHD underwent late gestational fetal cardiovascular magnetic resonance (CMR) to measure vessel blood flow and oxygen content. Superior vena cava (SVC) flow was used as a proxy for cerebral blood flow. Primary outcomes were 18-month mortality and Bayley Scales of Infant Development-III assessment. RESULTS: A total of 144 fetuses with cyanotic CHD were assessed. By 18 months, 18 patients (12.5%) died. Early mortality was associated with reduced combined ventricular output (P = 0.01), descending aortic flow (P = 0.04), and umbilical vein flow (P = 0.03). Of the surviving patients, 71 had ND outcomes assessed. Cerebral oxygen delivery was the fetal hemodynamic variable most strongly associated with cognitive, language, and motor outcomes (P < 0.05). Fetal SVC flow was also associated with cognitive, language, and motor outcomes (P < 0.01), and it remained an independent predictor of cognitive (P = 0.002) and language (P = 0.04) outcomes after adjusting for diagnosis. Diminished SVC flow also performed better than other fetal CMR and echocardiographic predictors of cognitive ND delay (receiver-operating characteristic curve area: 0.85; SE 0.05). CONCLUSIONS: Among fetuses with cyanotic CHD, diminished fetal combined ventricular output is associated with mortality, whereas cerebral blood flow and oxygen delivery are associated with early cognitive, language, and motor development at 18 months of age. These results support the inclusion of fetal CMR to help identify patients at risk of adverse ND outcomes.


Heart Defects, Congenital , Vena Cava, Superior , Pregnancy , Infant , Female , Child , Humans , Vena Cava, Superior/diagnostic imaging , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnosis , Hemodynamics/physiology , Fetus , Oxygen
2.
Circ Cardiovasc Imaging ; 14(7): e012411, 2021 07.
Article En | MEDLINE | ID: mdl-34187165

BACKGROUND: Identifying fetuses at risk of severe neonatal coarctation of the aorta (CoA) can be lifesaving but is notoriously challenging in clinical practice with a high rate of false positives. Novel fetal 3-dimensional and phase-contrast magnetic resonance imaging (MRI) offers an unprecedented means of assessing the human fetal cardiovascular system before birth. We performed detailed MRI assessment of fetal vascular morphology and flows in a cohort of fetuses with suspected CoA, correlated with the need for postnatal intervention. METHODS: Women carrying a fetus with suspected CoA on echocardiography were referred for MRI assessment between 26 and 36 weeks of gestation, including high-resolution motion-corrected 3-dimensional volumes of the fetal heart and phase-contrast flow sequences gated with metric optimized gating. The relationship between aortic geometry and vascular flows was then analyzed and compared with postnatal outcome. RESULTS: Seventy-two patients (51 with suspected fetal CoA and 21 healthy controls) underwent fetal MRI with motion-corrected 3-dimensional vascular reconstructions. Vascular flow measurements from phase-contrast sequences were available in 53 patients. In the CoA group, 25 of 51 (49%) required surgical repair of coarctation after birth; the remaining 26 of 51 (51%) were discharged without neonatal intervention. Reduced blood flow in the fetal ascending aorta and at the aortic isthmus was associated with increasing angulation (P=0.005) and proximal displacement (P=0.006) of the isthmus and was seen in both true positive and false positive cases. A multivariate logistic regression model including aortic flow and isthmal displacement explained 78% of the variation in outcome and correctly predicted the need for intervention in 93% of cases. CONCLUSIONS: Reduced blood flow though the left heart is associated with important configurational changes at the aortic isthmus in fetal life, predisposing to CoA when the arterial duct closes after birth. Novel fetal MRI techniques may have a role in both understanding and accurately predicting severe neonatal CoA.


Aorta, Thoracic/diagnostic imaging , Aortic Coarctation/diagnostic imaging , Fetal Heart/diagnostic imaging , Magnetic Resonance Imaging , Prenatal Diagnosis , Aorta, Thoracic/abnormalities , Aorta, Thoracic/physiopathology , Aortic Coarctation/physiopathology , Case-Control Studies , Female , Fetal Heart/abnormalities , Fetal Heart/physiopathology , Gestational Age , Humans , Models, Cardiovascular , Patient-Specific Modeling , Predictive Value of Tests , Pregnancy , Prospective Studies , Regional Blood Flow
4.
Nat Commun ; 11(1): 4992, 2020 10 05.
Article En | MEDLINE | ID: mdl-33020487

Prenatal detection of congenital heart disease facilitates the opportunity for potentially life-saving care immediately after the baby is born. Echocardiography is routinely used for screening of morphological malformations, but functional measurements of blood flow are scarcely used in fetal echocardiography due to technical assumptions and issues of reliability. Magnetic resonance imaging (MRI) is readily used for quantification of abnormal blood flow in adult hearts, however, existing in utero approaches are compromised by spontaneous fetal motion. Here, we present and validate a novel method of MRI velocity-encoding combined with a motion-robust reconstruction framework for four-dimensional visualization and quantification of blood flow in the human fetal heart and major vessels. We demonstrate simultaneous 4D visualization of the anatomy and circulation, which we use to quantify flow rates through various major vessels. The framework introduced here could enable new clinical opportunities for assessment of the fetal cardiovascular system in both health and disease.


Fetal Heart/diagnostic imaging , Fetal Heart/physiology , Four-Dimensional Computed Tomography/methods , Magnetic Resonance Imaging, Cine/methods , Blood Flow Velocity , Blood Vessels/diagnostic imaging , Blood Vessels/physiology , Female , Gestational Age , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/physiopathology , Humans , Phantoms, Imaging , Pregnancy , Prenatal Diagnosis
5.
Top Magn Reson Imaging ; 28(5): 235-244, 2019 Oct.
Article En | MEDLINE | ID: mdl-31592990

Magnetic resonance imaging (MRI) is an appealing technology for fetal cardiovascular assessment. It can be used to visualize fetal cardiac and vascular anatomy, to quantify fetal blood flow, and to quantify fetal blood oxygen saturation and hematocrit. However, there are practical limitations to the use of conventional MRI for fetal cardiovascular assessment, including the small size and high heart rate of the human fetus, the lack of conventional cardiac gating methods to synchronize data acquisition, and the potential corruption of MRI data due to maternal respiration and unpredictable fetal movements. In this review, we discuss recent technical advances in accelerated imaging, image reconstruction, cardiac gating, and motion compensation that have enabled dynamic MRI of the fetal heart.


Fetal Heart/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Magnetic Resonance Imaging/methods , Prenatal Diagnosis/methods , Female , Fetal Heart/embryology , Humans , Motion
6.
Magn Reson Med ; 82(3): 1055-1072, 2019 09.
Article En | MEDLINE | ID: mdl-31081250

PURPOSE: To develop an MRI acquisition and reconstruction framework for volumetric cine visualization of the fetal heart and great vessels in the presence of maternal and fetal motion. METHODS: Four-dimensional (4D) depiction was achieved using a highly-accelerated multi-planar real-time balanced steady-state free precession acquisition combined with retrospective image-domain techniques for motion correction, cardiac synchronization and outlier rejection. The framework was validated using a numerical phantom and evaluated in a study of 20 mid- to late-gestational age human fetal subjects (23-33 weeks gestational age). Reconstructed MR data were compared with matched ultrasound. A preliminary assessment of flow-sensitive reconstruction using the velocity information encoded in the phase of real-time images is included. RESULTS: Reconstructed 4D data could be visualized in any two-dimensional plane without the need for highly specific scan plane prescription prior to acquisition or for maternal breath hold to minimize motion. Reconstruction was fully automated aside from user-specified masks of the fetal heart and chest. The framework proved robust when applied to fetal data and simulations confirmed that spatial and temporal features could be reliably recovered. Evaluation suggested the reconstructed framework has the potential to be used for comprehensive assessment of the fetal heart, either as an adjunct to ultrasound or in combination with other MRI techniques. CONCLUSIONS: The proposed methods show promise as a framework for motion-compensated 4D assessment of the fetal heart and great vessels.


Fetal Heart/diagnostic imaging , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Computer Simulation , Female , Humans , Movement/physiology , Phantoms, Imaging , Pregnancy
7.
Lancet ; 393(10181): 1619-1627, 2019 Apr 20.
Article En | MEDLINE | ID: mdl-30910324

BACKGROUND: Two-dimensional (2D) ultrasound echocardiography is the primary technique used to diagnose congenital heart disease before birth. There is, however, a longstanding need for a reliable form of secondary imaging, particularly in cases when more detailed three-dimensional (3D) vascular imaging is required, or when ultrasound windows are of poor diagnostic quality. Fetal MRI, which is well established for other organ systems, is highly susceptible to fetal movement, particularly for 3D imaging. The objective of this study was to investigate the combination of prenatal MRI with novel, motion-corrected 3D image registration software, as an adjunct to fetal echocardiography in the diagnosis of congenital heart disease. METHODS: Pregnant women carrying a fetus with known or suspected congenital heart disease were recruited via a tertiary fetal cardiology unit. After initial validation experiments to assess the general reliability of the approach, MRI data were acquired in 85 consecutive fetuses, as overlapping stacks of 2D images. These images were then processed with a bespoke open-source reconstruction algorithm to produce a super-resolution 3D volume of the fetal thorax. These datasets were assessed with measurement comparison with paired 2D ultrasound, structured anatomical assessment of the 2D and 3D data, and contemporaneous, archived clinical fetal MRI reports, which were compared with postnatal findings after delivery. FINDINGS: Between Oct 8, 2015, and June 30, 2017, 101 patients were referred for MRI, of whom 85 were eligible and had fetal MRI. The mean gestational age at the time of MRI was 32 weeks (range 24-36). High-resolution (0·50-0·75 mm isotropic) 3D datasets of the fetal thorax were generated in all 85 cases. Vascular measurements showed good overall agreement with 2D echocardiography in 51 cases with paired data (intra-class correlation coefficient 0·78, 95% CI 0·68-0·84), with fetal vascular structures more effectively visualised with 3D MRI than with uncorrected 2D MRI (657 [97%] of 680 anatomical areas identified vs 358 [53%] of 680 areas; p<0·0001). When a structure of interest was visualised in both 2D and 3D data (n=358), observers gave a higher diagnostic quality score for 3D data in 321 (90%) of cases, with 37 (10%) scores tied with 2D data, and no lower scores than for 2D data (Wilcoxon signed rank test p<0·0001). Additional anatomical features were described in ten cases, of which all were confirmed postnatally. INTERPRETATION: Standard fetal MRI with open-source image processing software is a reliable method of generating high-resolution 3D imaging of the fetal vasculature. The 3D volumes produced show good spatial agreement with ultrasound, and significantly improved visualisation and diagnostic quality compared with source 2D MRI data. This freely available combination requires minimal infrastructure, and provides safe, powerful, and highly complementary imaging of the fetal cardiovascular system. FUNDING: Wellcome Trust/EPSRC Centre for Medical Engineering, National Institute for Health Research.


Cardiotocography/methods , Fetal Heart/diagnostic imaging , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging , Female , Fetal Heart/pathology , Gestational Age , Heart Defects, Congenital/diagnosis , Humans , Pregnancy , Prospective Studies , Ultrasonography, Prenatal
8.
Magn Reson Med ; 79(1): 327-338, 2018 Jan.
Article En | MEDLINE | ID: mdl-28370252

PURPOSE: Development of a MRI acquisition and reconstruction strategy to depict fetal cardiac anatomy in the presence of maternal and fetal motion. METHODS: The proposed strategy involves i) acquisition and reconstruction of highly accelerated dynamic MRI, followed by image-based ii) cardiac synchronization, iii) motion correction, iv) outlier rejection, and finally v) cardiac cine reconstruction. Postprocessing entirely was automated, aside from a user-defined region of interest delineating the fetal heart. The method was evaluated in 30 mid- to late gestational age singleton pregnancies scanned without maternal breath-hold. RESULTS: The combination of complementary acquisition/reconstruction and correction/rejection steps in the pipeline served to improve the quality of the reconstructed 2D cine images, resulting in increased visibility of small, dynamic anatomical features. Artifact-free cine images successfully were produced in 36 of 39 acquired data sets; prolonged general fetal movements precluded processing of the remaining three data sets. CONCLUSIONS: The proposed method shows promise as a motion-tolerant framework to enable further detail in MRI studies of the fetal heart and great vessels. Processing data in image-space allowed for spatial and temporal operations to be applied to the fetal heart in isolation, separate from extraneous changes elsewhere in the field of view. Magn Reson Med 79:327-338, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Cardiac-Gated Imaging Techniques , Fetal Heart/diagnostic imaging , Image Processing, Computer-Assisted , Magnetic Resonance Imaging, Cine , Prenatal Diagnosis/methods , Algorithms , Artifacts , Female , Humans , Image Interpretation, Computer-Assisted , Models, Statistical , Motion , Pregnancy , Pregnancy Trimester, Third , Probability , Reproducibility of Results
9.
Prenat Diagn ; 36(10): 916-925, 2016 Oct.
Article En | MEDLINE | ID: mdl-27521762

OBJECTIVES: Fetal cardiovascular magnetic resonance imaging (MRI) offers a potential alternative to echocardiography, although in practice, its use has been limited. We sought to explore the need for additional imaging in a tertiary fetal cardiology unit and the usefulness of standard MRI sequences. METHODS: Cases where the diagnosis was not fully resolved using echocardiography were referred for MRI. Following a three-plane localiser, fetal movement was assessed with a balanced steady-state free precession (bSSFP) cine. Single-shot fast spin echo and bSSFP sequences were used for diagnostic imaging. RESULTS: Twenty-two fetal cardiac MRIs were performed over 12 months, at mean gestation of 32 weeks (26-38 weeks). The majority of referrals were for suspected vascular abnormalities (17/22), particularly involving the aortic arch (n = 10) and pulmonary vessels (n = 4). Single-shot fast spin echo sequences produced 'black-blood' images, useful for examining the extracardiac vasculature in these cases. BSSFP sequences were more useful for intracardiac structures. Real-time SSFP allowed for dynamic assessment of structures such as cardiac masses, with enhancement patterns also allowing for tissue characterisation in these cases. CONCLUSIONS: Fetal vascular abnormalities such as coarctation can be difficult to diagnose by using ultrasound. Fetal MRI may have an adjunctive role in the evaluation of the extracardiac vascular anatomy and tissue characterisation. © 2016 The Authors. Prenatal Diagnosis published by John Wiley & Sons, Ltd.


Echocardiography/methods , Fetal Heart/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Magnetic Resonance Imaging/methods , Aorta, Thoracic/abnormalities , Aorta, Thoracic/diagnostic imaging , Aortic Coarctation/diagnostic imaging , Diverticulum/diagnostic imaging , Female , Fetal Heart/abnormalities , Heart Septal Defects, Ventricular/diagnostic imaging , Humans , Pregnancy , Pregnancy Trimester, Second , Pregnancy Trimester, Third , Prenatal Diagnosis , Pulmonary Artery/abnormalities , Pulmonary Artery/diagnostic imaging , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging , Ultrasonography, Prenatal
10.
Cardiol Young ; 25(4): 737-44, 2015 Apr.
Article En | MEDLINE | ID: mdl-24932863

OBJECTIVES: To investigate the relationship between foetal haemodynamics and postnatal clinical presentation in patients with transposition of the great arteries using phase-contrast cardiovascular magnetic resonance. BACKGROUND: A severe and irreversible form of persistent pulmonary hypertension of the newborn occurs in up to 5% of patients with transposition and remains an important cause of morbidity and mortality in these infants. Restriction at the foramen ovale and ductus arteriosus has been identified as a risk factor for the development of pulmonary hypertension, and this can now be studied with magnetic resonance imaging using a new technique called metric optimised gating. METHODS: Blood flow was measured in the major vessels of four foetuses with transposition with intact ventricular septum (gestational age range: 35-38 weeks) and compared with values from 12 normal foetuses (median gestational age: 37 weeks; range: 34-40 weeks). RESULTS: We found significantly reduced flows in the ductus arteriosus (p<0.01) and foramen ovale (p=0.03) and increased combined ventricular output (p=0.01), ascending aortic (p=0.001), descending aortic (p=0.03), umbilical vein (p=0.03), and aorto-pulmonary collateral (p<0.001) flows in foetuses with transposition compared with normals. The foetus with the lowest foramen ovale shunt and highest aorto-pulmonary collateral flow developed fatal pulmonary vascular disease. CONCLUSIONS: We found limited mixing between the systemic and pulmonary circulations in a small group of late-gestation foetuses with transposition. We propose that the resulting hypoxia of the pulmonary circulation could be the driver behind increased aorto-pulmonary collateral flow and contribute to the development of pulmonary vascular disease in some foetuses with transposition.


Pulmonary Artery/physiopathology , Pulmonary Circulation/physiology , Transposition of Great Vessels/complications , Transposition of Great Vessels/physiopathology , Case-Control Studies , Female , Gestational Age , Hemodynamics , Humans , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/congenital , Infant, Newborn , Magnetic Resonance Imaging , Ontario , Pregnancy , Pulmonary Artery/abnormalities , Pulmonary Veno-Occlusive Disease/complications , Pulmonary Veno-Occlusive Disease/congenital , Regional Blood Flow/physiology , Transposition of Great Vessels/surgery , Treatment Outcome
11.
J Cardiovasc Magn Reson ; 15: 65, 2013 Jul 27.
Article En | MEDLINE | ID: mdl-23890187

BACKGROUND: The distribution of blood flow in fetuses with congenital heart disease (CHD) is likely to influence fetal growth, organ development, and postnatal outcome, but has previously been difficult to study. We present the first measurements of the distribution of the fetal circulation in left-sided CHD made using phase contrast cardiac magnetic resonance (CMR). METHODS: Twenty-two fetuses with suspected left-sided CHD and twelve normal controls underwent fetal CMR and echocardiography at a mean of 35 weeks gestation (range 30-39 weeks). RESULTS: Fetuses with left-sided CHD had a mean combined ventricular output 19% lower than normal controls (p < 0.01). In fetuses with left-sided CHD with pulmonary venous obstruction, pulmonary blood flow was significantly lower than in those with left-sided CHD without pulmonary venous obstruction (p < 0.01). All three fetuses with pulmonary venous obstruction had pulmonary lymphangectasia by fetal CMR and postnatal histology. Fetuses with small but apex forming left ventricles with left ventricular outflow tract or aortic arch obstruction had reduced ascending aortic and foramen ovale flow compared with normals (p < 0.01). Fetuses with left-sided CHD had more variable superior vena caval flows than normal controls (p < 0.05). Six fetuses with CHD had brain weights at or below the 5th centile for gestational age, while none of the fetuses in the normal control group had brain weights below the 25th centile. CONCLUSIONS: Measurement of the distribution of the fetal circulation in late gestation left-sided CHD is feasible with CMR. We demonstrated links between fetal blood flow distribution and postnatal course, and examined the relationship between fetal hemodynamics and lung and brain development. CMR enhances our understanding of pathophysiology of the fetal circulation and, with more experience, may help with the planning of perinatal management and fetal counselling.


Coronary Circulation , Heart Defects, Congenital/diagnosis , Magnetic Resonance Imaging/methods , Blood Flow Velocity , Cardiac-Gated Imaging Techniques , Case-Control Studies , Echocardiography , Female , Gestational Age , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/pathology , Humans , Image Interpretation, Computer-Assisted , Pregnancy , Ultrasonography, Prenatal
12.
Magn Reson Med ; 70(6): 1598-607, 2013 Dec.
Article En | MEDLINE | ID: mdl-23382068

PURPOSE: Advances in fetal cardiovascular magnetic resonance imaging have been limited by the absence of a reliable cardiac gating signal. The purpose of this work was to develop and validate metric-optimized gating (MOG) for cine imaging of the fetal heart. THEORY AND METHODS: Cine MR and electrocardiogram data were acquired in healthy adult volunteers for validation of the MOG method. Comparison of MOG and electrocardiogram reconstructions was performed based on the image quality for each method, and the difference between MOG and electrocardiogram trigger times. Fetal images were also acquired, their quality evaluated by experienced radiologists, and the theoretical error in the MOG trigger times were calculated. RESULTS: Excellent agreement between electrocardiogram and MOG reconstructions was observed. The experimental errors in adult MOG trigger times for all five volunteers were ± (7, 25, 17, 8, and 13) ms. Fetal images captured normal and diseased cardiac dynamics. CONCLUSION: MOG for cine imaging of the fetal myocardium was developed and validated in adults. Using MOG, the first gated MR images of the human fetal myocardium were obtained. Small moving structures were visualized during radial contraction, thus capturing normal fetal cardiac wall motion and permitting assessment of cardiac function.


Algorithms , Cardiac-Gated Imaging Techniques/methods , Fetal Heart/anatomy & histology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Prenatal Diagnosis/methods , Adult , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
13.
J Cardiovasc Magn Reson ; 14: 79, 2012 Nov 26.
Article En | MEDLINE | ID: mdl-23181717

BACKGROUND: We present the first phase contrast (PC) cardiovascular magnetic resonance (CMR) measurements of the distribution of blood flow in twelve late gestation human fetuses. These were obtained using a retrospective gating technique known as metric optimised gating (MOG). METHODS: A validation experiment was performed in five adult volunteers where conventional cardiac gating was compared with MOG. Linear regression and Bland Altman plots were used to compare MOG with the gold standard of conventional gating. Measurements using MOG were then made in twelve normal fetuses at a median gestational age of 37 weeks (range 30-39 weeks). Flow was measured in the major fetal vessels and indexed to the fetal weight. RESULTS: There was good correlation between the conventional gated and MOG measurements in the adult validation experiment (R=0.96). Mean flows in ml/min/kg with standard deviations in the major fetal vessels were as follows: combined ventricular output (CVO) 540 ± 101, main pulmonary artery (MPA) 327 ± 68, ascending aorta (AAo) 198 ± 38, superior vena cava (SVC) 147 ± 46, ductus arteriosus (DA) 220 ± 39,pulmonary blood flow (PBF) 106 ± 59,descending aorta (DAo) 273 ± 85, umbilical vein (UV) 160 ± 62, foramen ovale (FO)107 ± 54. Results expressed as mean percentages of the CVO with standard deviations were as follows: MPA 60 ± 4, AAo37 ± 4, SVC 28 ± 7, DA 41 ± 8, PBF 19 ± 10, DAo50 ± 12, UV 30 ± 9, FO 21 ± 12. CONCLUSION: This study demonstrates how PC CMR with MOG is a feasible technique for measuring the distribution of the normal human fetal circulation in late pregnancy. Our preliminary results are in keeping with findings from previous experimental work in fetal lambs.


Cardiac-Gated Imaging Techniques , Fetus/blood supply , Magnetic Resonance Imaging, Cine , Perfusion Imaging/methods , Prenatal Diagnosis/methods , Adult , Blood Flow Velocity , Blood Vessels/physiology , Cross-Sectional Studies , Feasibility Studies , Female , Fetal Heart/physiology , Fetal Weight , Gestational Age , Humans , Linear Models , Observer Variation , Predictive Value of Tests , Pregnancy , Prospective Studies , Regional Blood Flow , Reproducibility of Results
14.
Magn Reson Med ; 64(5): 1304-14, 2010 Nov.
Article En | MEDLINE | ID: mdl-20632406

Phase-contrast magnetic resonance imaging can be used to complement echocardiography for the evaluation of the fetal heart. Cardiac imaging typically requires gating with peripheral hardware; however, a gating signal is not readily available in utero. No successful application of existing technologies to human fetal phase-contrast magnetic resonance imaging has been reported to date in the literature. The purpose of this work is to develop a technique for phase-contrast magnetic resonance imaging of the fetal heart that does not require measurement of a gating signal. Metric optimized gating involves acquiring data without gating and retrospectively determining the proper reconstruction by optimizing an image metric. The effects of incorrect gating on phase contrast images were investigated, and the time-entropy of the series of images was found to provide a good measure of the level of corruption. The technique was validated with a pulsatile flow phantom, experiments with adult volunteers, and in vivo application in the fetal population. Images and flow curves from these measurements are presented. Additionally, numerical simulations were used to investigate the degree to which heart rate variability affects the reconstruction process. Metric optimized gating enables imaging with conventional phase-contrast magnetic resonance imaging sequences in the absence of a gating signal, permitting flow measurements in the great vessels in utero.


Algorithms , Cardiac-Gated Imaging Techniques/methods , Heart/embryology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Prenatal Diagnosis/methods , Female , Heart/anatomy & histology , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
15.
Magn Reson Imaging ; 28(1): 95-102, 2010 Jan.
Article En | MEDLINE | ID: mdl-19553052

Self-gating is investigated to improve the velocity resolution of real-time Fourier velocity encoding measurements in the absence of a reliable electrocardiogram waveform (e.g., fetal magnetic resonance or severe arrhythmia). Real-time flow data are acquired using interleaved k-space trajectories which share a common path near the origin of k-space. These common data provide a rapid self-gating signal that can be used to combine the interleaved data. The combined interleaves cover a greater area of k-space than a single real-time acquisition, thereby providing higher velocity resolution for a given aliasing velocity and temporal resolution. For example, this approach provided velocity spectra with a temporal resolution of 19 ms and velocity resolution of 22 cm/s over an 818 cm/s field-of-view. The method was validated experimentally using a computer-controlled pulsatile flow apparatus and applied in vivo to measure aortic-valve flow in a healthy volunteer.


Algorithms , Aortic Valve/anatomy & histology , Aortic Valve/physiology , Blood Flow Velocity/physiology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Rheology/methods , Fourier Analysis , Humans , Image Enhancement/methods , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
16.
Magn Reson Med ; 61(5): 1249-54, 2009 May.
Article En | MEDLINE | ID: mdl-19253385

Regional pulmonary blood flow can be assessed using both dynamic contrast-enhanced (DCE) MR and phase-contrast (PC) MR. These methods provide somewhat complementary information: DCE MR can assess flow over the entire lung while PC MR can detect rapid changes in flow to a targeted region. Although both methods are considered accurate, one may be more feasible than the other depending on pathology, patient condition, and availability of an intravenous route. The objective of this study was to establish a consensus between the two methods by comparing paired DCE MR and PC MR measurements of relative blood flow in Yorkshire piglets (N = 5, age = 7 days, weight = 3.3 +/- 0.6 kg) under various physiological states including regional lung collapse. A strong correlation (R(2) = 0.71, P < 0.01) was observed between the methods. In conclusion, DCE MR and PC MR provide a consistent measure of changes in regional pulmonary blood flow.


Blood Flow Velocity , Gadolinium DTPA , Magnetic Resonance Angiography/methods , Perfusion Imaging/methods , Pulmonary Artery/physiopathology , Pulmonary Atelectasis/diagnosis , Pulmonary Atelectasis/physiopathology , Animals , Contrast Media , Reproducibility of Results , Sensitivity and Specificity , Swine
17.
Magn Reson Imaging ; 27(1): 38-47, 2009 Jan.
Article En | MEDLINE | ID: mdl-18650044

An automated method was evaluated to detect blood flow in small pulmonary arteries and classify each as artery or vein, based on a temporal correlation analysis of their blood-flow velocity patterns. The method was evaluated using velocity-sensitive phase-contrast magnetic resonance data collected in vitro with a pulsatile flow phantom and in vivo in 11 human volunteers. The accuracy of the method was validated in vitro, which showed relative velocity errors of 12% at low spatial resolution (four voxels per diameter), but was reduced to 5% at increased spatial resolution (16 voxels per diameter). The performance of the method was evaluated in vivo according to its reproducibility and agreement with manual velocity measurements by an experienced radiologist. In all volunteers, the correlation analysis was able to detect and segment peripheral pulmonary vessels and distinguish arterial from venous velocity patterns. The intrasubject variability of repeated measurements was approximately 10% of peak velocity, or 2.8 cm/s root-mean-variance, demonstrating the high reproducibility of the method. Excellent agreement was obtained between the correlation analysis and radiologist measurements of pulmonary velocities, with a correlation of R2=0.98 (P<.001) and a slope of 0.99+/-0.01.


Blood Flow Velocity , Magnetic Resonance Imaging, Cine/methods , Pulmonary Artery/physiology , Adult , Humans , Image Processing, Computer-Assisted , Phantoms, Imaging , Pulsatile Flow , Reproducibility of Results
...